Fault
|
Possible cause
|
Diagnostic clue
|
Corrective action
|
No plating at all
|
Open circuit |
If you are using a MultiPlater, an open circuit is indicated by a continuous red light. A conventional power supply will show zero amps. |
Check the workpiece connection, electrode and leads. Make sure the swab is fully wetted with plating solution so that electrical contact is maintained. If you are unsure whether the surface itself is electrically conductive, check it with the Conductivity Tester before continuing. |
| Connections reversed |
The MultiPlater will still show a green light and a conventional power supply will still show amps. |
Correct the polarity. Nickel and stainless steel will usually only need to be reactivated. Brass and copper may be etched and will need to be repolished before replating. |
| Swab not fully wetted with plating solution |
No current flows if the plating solution does not make contact between the electrode and the workpiece. |
Make sure the swab is fully wetted with plating solution. |
| Trying to plate directly on to a PVD coating |
Little or no gold may deposit. Irregular swirling or streaked marks may appear and the swab may become dark or gold-coloured as particles of the PVD coating detach. |
Do not brush plate directly on to the PVD coating. Remove the PVD coating completely, then prepare and plate the underlying surface. |
| Trying to plate directly on to a passive or difficult-to-plate metal or alloy |
Electrical contact is present, but little or no gold plating takes place. |
Use the appropriate preparation process before gold plating. More-passive stainless steels require Gold Strike, aluminium requires Zincate Dip, and other difficult metals require their appropriate preparation process. Yellow Gold Brush Plating Solution can, however, be plated directly on to suitable less-passive stainless steels. |
| Platinum coating on the electrode completely worn away |
If you are using a MultiPlater, a continuous red light will show. A conventional power supply will show zero amps even though the electrical connections are sound. |
Replace the worn electrode. Platinum is the preferred electrode for Yellow Gold Brush Plating Solution. |
| Existing clear coat or E-coating on the surface |
A continuous clear insulating coating prevents electrical contact with the underlying metal. The coating can be difficult to see and the underlying surface may still look metallic. |
Completely remove the clear coat or E-coating to expose the underlying metal, then prepare and activate that metal using the appropriate process before gold plating. A Conductivity Tester can be used to check the surface. |
Plating is slow
|
Gold content of the solution is depleted |
The solution has been used repeatedly and the plating rate has gradually become slower. |
Replace with fresh Yellow Gold Brush Plating Solution, or increase the voltage gradually within the recommended 3–4.5 V operating range. Take care not to burn the deposit. |
| Swab is not fully wetted/saturated with plating solution |
Plating takes place, but more slowly than expected. |
Keep the swab fully wetted and saturated with plating solution throughout the plating process. |
| Swab is too small for the area being plated |
Individual areas plate normally, but building the required thickness over the complete area takes a long time. |
Use a larger swab where practical. |
| Voltage too low |
There is full electrical contact and plating is taking place normally, but the deposition rate is slower than expected. |
Increase the voltage gradually within the recommended operating range of 3–4.5 V. Stop increasing the voltage if the deposit begins to darken or burn. |
| Swab is not being kept in consistent contact with the workpiece |
Plating occurs when the swab is in good contact, but overall build-up is slow because contact is weak or intermittent. |
Keep the fully wetted swab in consistent contact with the surface while moving it continuously over the area being plated. |
| Solution or workpiece is too cold |
Plating is slower than usual even though the solution, swab and electrical contact are otherwise satisfactory. |
Allow the solution and workpiece to reach the normal operating temperature range of 14–25 °C before plating. |
| Expected plating time is shorter than the process actually requires |
The plating is progressing normally, but the time allowed is too short for the area and thickness required. |
Use the Yellow Gold Brush Plating Calculator to estimate the plating time from the area and required thickness. |
| High resistance in an electrical connection |
Plating is unusually slow despite otherwise normal conditions. A poor or partially oxidised connection may become noticeably warm or hot. |
Switch off the power and check all electrical connections. Clean or replace any oxidised, loose or damaged contacts before continuing. |
Plating is patchy or uneven
|
Insufficient activation of the surface |
Gold plates readily on some areas but is reluctant to start, or fails to plate, on others. |
Reactivate the surface before plating. Follow the appropriate preparation method in the Process Sequences tab. |
| Surface not properly cleaned |
Plating is patchy or refuses to deposit in some areas. Oil, grease or other contamination interferes with plating and may transfer to the swab. |
Improve the cleaning process. Wash a contaminated swab thoroughly with concentrated detergent and rinse very well with clean water before using it again. |
| Trying to plate directly on to a PVD coating |
Little or no gold may deposit and irregular swirling or streaked marks may appear. |
Remove the PVD coating completely, then prepare and plate the underlying surface. |
| Residual brighteners or other strongly adherent residues from previous tank plating |
The surface has recently been tank plated, particularly with silver, and the subsequent gold deposits unevenly or refuses to plate properly in some areas. |
Thoroughly remove residual plating additives before gold plating. Where practical, rub the surface with MPU before proceeding. |
| Swab contaminated from a previous process |
The swab is discoloured or has retained foreign material from an earlier process. |
Wash the swab thoroughly with concentrated detergent and rinse very well with clean water. Replace it if the contamination cannot be removed. |
| Clear coat or E-coating only partially removed |
Gold plates on exposed areas but not where the insulating coating remains. |
Completely remove all remaining clear coat or E-coating, then prepare and activate the exposed metal before replating. |
Deposit is dark/brown/burnt
|
Voltage too high |
The gold deposit becomes dark, brown or burnt, particularly on corners, points and other high-current areas. |
Reduce the plating voltage. Keep within the recommended operating range of 3–4.5 V. For minor burning, lightly polish the affected area with MPU Coarse, MPU or MPU Fine as appropriate, rinse thoroughly with clean water and continue plating without allowing the surface to dry. |
| Brushing action too slow or incorrect |
Dark or burnt areas develop during plating, particularly where the swab is moving slowest relative to the workpiece. |
Increase the speed of the brushing action and keep the swab moving continuously in a circular motion over the surface. |
| Iron contamination |
The deposit develops an abnormal grey-brown appearance, particularly if an unsuitable stainless steel electrode has been used. |
Stop using the stainless steel electrode and discard contaminated solution. Use a platinum electrode, which is preferred, or a suitable carbon electrode. |
Plating is dull
|
Underlying surface is dull or porous |
The gold deposit is sound and uniform but reflects the dull or porous finish of the underlying surface. |
Polish the surface to the required finish. Where possible, use MPU Coarse, MPU or MPU Fine as appropriate. After polishing with an MPU product, rinse thoroughly with clean water and proceed directly to plating without allowing the surface to dry. If a proprietary metal polish such as Autosol is used, the surface must be thoroughly cleaned and activated again before plating. If the underlying surface is porous, an appropriate intermediate plating layer may be required before final polishing and gold plating. |
| Plating solution has deteriorated with age |
The solution still plates, but the deposit is noticeably less satisfactory than when the solution was fresh. Yellow Gold Brush Plating Solution has a shelf life of 3 months. |
Replace with fresh Yellow Gold Brush Plating Solution. |
Plating fails the adhesive tape test or peels
|
Existing plating or coating is poorly adhered |
The plating fails the adhesive tape test or peels. Examine the underside of the material removed by the tape. Its colour can help identify which plated layer has failed. For example, a gold-coloured underside indicates failure at the gold interface, while a silver or copper-coloured underside indicates that the silver or copper plated layer respectively has failed at the interface beneath it. There may already be signs of blistering, flaking or delamination before gold plating. |
Remove all loose or poorly adhered plating back to a sound surface before replating. A new gold layer cannot improve the adhesion of an unstable coating underneath it. |
| Plating directly on to a difficult-to-plate surface or coating |
Gold may initially appear to plate but adhesion is poor and it subsequently rubs off or peels. |
Identify the underlying surface and use the appropriate preparation process. PVD coatings should normally be completely removed. |
| Surface not properly activated, or allowed to dry after activation |
Gold plates but adhesion is poor. This is particularly important with stainless steel and nickel. |
Reactivate immediately before gold plating. After activation, rinse as required but do not allow the work to dry before plating. |
| Immersion deposit from contaminated process solution |
A thin, poorly adherent immersion layer forms before gold plating, so the subsequent gold can peel or rub off. |
Replace the contaminated cleaner or activator, then prepare and reactivate the work before replating. Keep process solutions used for ferrous and non-ferrous metals appropriately separated. |
Deposit colour is wrong
|
Thin gold deposit alloying with underlying silver |
The deposited colour is altered when a thin layer of Yellow Gold is applied directly over silver. |
Continue plating to build a thicker Yellow Gold deposit until the characteristic yellow gold colour develops. |
| Gold deposit is extremely thin, allowing the colour of the underlying surface to show through |
The underlying surface remains visible through the gold and influences the apparent colour. |
Continue plating to increase the gold thickness until the underlying colour no longer affects the appearance. |
| Solution contaminated with another metal |
The gold plates normally but develops an unexpected colour. Contamination can be introduced by a swab previously used with another plating solution or by poor rinsing between processes. |
Prevent carry-over between processes. Thoroughly wash and rinse swabs before using them with another solution and rinse the workpiece thoroughly. Replace significantly contaminated Yellow Gold Brush Plating Solution. |
| Incorrect electrode material |
The deposit develops an abnormal colour during plating. |
Use a platinum electrode (preferred) or a suitable carbon electrode. Replace the solution if it has become significantly contaminated by an unsuitable electrode. |
| Solution composition has changed as it becomes exhausted |
The deposited shade gradually changes as the solution is repeatedly used. |
Do not attempt to adjust or rebalance the alloy composition. Replace with fresh Yellow Gold Brush Plating Solution. |
Poor coverage
|
Swab not fully wetted with plating solution |
Gold plates where good solution contact is made but fails or becomes weak elsewhere. |
Fully saturate the swab and keep it adequately wetted throughout plating. |
| Intermittent electrical contact |
Plating repeatedly starts and stops as the swab moves across the work. With a MultiPlater, the warning beep sounds and the indicator changes as contact is lost and restored. |
Check the workpiece connection and maintain continuous contact between the wetted swab and the workpiece. Use the Conductivity Tester if the conductivity of the surface is uncertain. |
| Swab too small for the area being plated |
Individual areas plate normally, but obtaining uniform coverage over the complete area is difficult or excessively slow. |
Use a larger swab appropriate to the area being plated. |
Scratchy plating
|
Particulate contamination of the swab |
Fine scratches appear as the swab passes over the surface. |
Replace the swab. Do not continue plating with a swab containing particulate contamination. |
| Swab stored alongside abrasives |
Scratching starts immediately with an otherwise apparently clean swab. |
Replace the swab and store plating swabs separately from abrasives, polishing compounds and other sources of particulate contamination. |
| Old silver-plating swab contains metallic silver particles |
An old silver swab has darkened or been exposed to light, allowing retained silver compounds to form metallic silver particles. |
Replace the swab. Do not try to recover a swab once metallic silver particles are trapped in it. |
Incorrect plating thickness
|
Incorrect plating area estimated |
The actual area being plated differs from the area assumed when estimating the required plating time. Irregular shapes, edges and recesses are easily underestimated. |
Estimate the total area being plated as accurately as possible. If you are unsure how to estimate the surface area of your workpiece, ask our Technical Assistant for help. |
| Thickness estimated from appearance |
The gold appears to have fully covered the surface, but the actual thickness differs from that required. |
Do not judge plating thickness from appearance alone. Where a specified thickness is important, verify the result by XRF or deposited weight. |
| Actual plating conditions differ from those used by the calculator |
The calculated time has been followed, but the resulting thickness differs from that expected because the actual plating conditions differ from those assumed by the calculator. |
Use the Yellow Gold Brush Plating Calculator as the starting point and keep the actual plating conditions as close as practical to those specified. Where thickness is critical, verify it by XRF or deposited weight. |
| Coulometer or calculator setting is incorrect |
Plating stops at the indicated charge or calculated time, but the measured deposit thickness is consistently too high or too low. |
Check that the correct Yellow Gold Brush Plating Solution settings, surface area and required thickness have been entered. If using a MultiPlater coulometer, check that the correct coulometer setting has been selected. |